Heating Service
Your Problem is Fixed Right
The First Time … or It’s Free!
Heating Service 24/7
Repair, Cleaning, Inspections & Maintenance
Flat Rate Pricing
Parts Replacement – Emergency Installations
Club Membership
Discounts
(click here)
Precision Tune ups
Reduce Diagnostic Fees
Save Money Now
A Reputation You Can Rely On Since 1985,
More Than 25 vehicles
Providing Service 24 hours, 7 days a week.

(click here)
We repair all makes and models
We specialize in: Improved Efficiency / Longer Lasting Systems
- Heating Specialists
- Heat Pump Boiler, Furnace and Installations, Service and Repair
- Natural Gas, Oil, Propane Forced Air Furnaces
- Electric Forced Air Furnaces
- Hot Water Forced Air Furnaces
- Hot Water Baseboard Installation
- Parts Replacement
- Emergency Installations
- Infra Red Gas Heaters
- Radiant Heat Loop Systems
- Humidifiers Space Guard Air Cleaners
We use an inspector camera to locate faulty heat exchangers while doing a furnace tune up.
See Video
http://www.youtube.com/user/seethehvacpros
Gas Furnace/Boiler 28 Point Tune Up
FURNACE/BOILER 28POINT TUNE UP and SAFETY INSPECTION
ITEM COOLING AND HEATING INSPECTION
1 VISUALLY INSPECT AND TEST CAPACITORS FOR LEAKAGE AND RUST
2 INSPECT READILY ACCESSIBLE DUCTS FOR OBVIOUS AIR LEAKS
3 COMPLETE OPERATIONS SEQUENCE CHECK
4 CHECK CRANKCASE HEATER FOR PROPER OPERATION
5 INSPECTION OF AIR FILTRATION SYSTEM
6 INSPECT BLOWER WHEEL
7 INSPECT BLOWER MOTOR AND RECORD AMP DRAW (LUBRICATE AS NEEDED)
8 REPLACEMENT OF FILTER PROVIDED BY CUSTOMER ON SITE AT TIME OF INSPECTION
9 INSPECT UNIT WIRING AND ELECTRICAL DISCONNECT
10 CHECK AND CALIBRATE THERMOSTAT AS REQUIRED
ITEM HEATING INSPECTION INCLUDES
11 INSPECT GAS LINES AND CONNECTIONS AT FURNACE/BOILER FOR LEAKS
12 CHECK HIGH LIMIT CONTROL (ADJUST AS NEEDED)
13 INSPECT BURNER IGNITION SYSTEM AND ASSEMBLY.
14 INSPECT GAS BURNERS
15 CHECK AND ADJUST MANIFOLD GAS PRESSURE
16 CHECK TEMPERATURE RISE ACROSS HEAT EXCHANGER FOR OVERHEATING
17 INSPECT HEAT EXCHANGER FOR SOOTING, CORROSION, CRACKS AND DEFORMITIES
18 INSPECT GAS VALVE FOR CORROSION, LEAKS, RESTRICTION OF GAS FLOW AND ABNORMAL NOISE
19 INSPECT FURNACE/BOILER WIRING ASSEMBLY FOR LOOSE CONNECTIONS
20 INSPECT FLUE AND VENTING FOR OBSTRUCTIONS AND LEAKS
21 CHECK (1) ELECTRICAL CIRCUIT TO FURNACE/BOILER. TEST ALL ELECTRICAL/SAFETY CIRCUITS/CONTROLS FOR PROPER OPERATION
22 INSPECT ENTIRE FURNACE/BOILER FOR LOOSE OR WORN PARTS AND ABNORMAL VIBRATIONS
23 TEST AND ADJUST THE UNIT FOR PEAK OPERATING EFFICIENCY
24 CHECK CARBON MONOXIDE EMISSION LEVEL FOR PASS/FAIL
25 CHECK DEFROST CYCLE AND REVERSING VALVE OPERATION (HEAT PUMPS ONLY)
26 TIGHTEN SCREW LUG TERMINALS IN CONDENSING UNIT (HEAT PUMPS ONLY)
27 CHECK REFRIGERANT LEVEL (HEAT PUMPS ONLY)
28 CHECK EMERGENCY HEAT SYSTEMS FOR PROPER OPERTION (HEAT PUMP ONLY)